RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 2017

Fagor alarm 2017: CNC RAM memory error

CNC 8055 CNC error · Fagor 8055/8055i

What it means

The 8055 memory self-test run at power-up or in diagnostics mode has found a defect in the CNC's RAM. Fagor's documented remedy is replacement of the CPU board by qualified service, since program and table integrity can no longer be guaranteed.

Likely causes

  • failed RAM devices on the CPU board
  • board damage from a past +5 V excursion or shorted feedback supply
  • poor edge contact/connector seating giving intermittent reads

Triage note: If it appeared after handling the unit, reseat the CPU board and check the internal +5 V before ordering a board.

Need the part urgently?

Send us alarm 2017 with your machine details — typical RFQ turnaround is 24–48h.