RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 0010

Fagor alarm 0010: Error when testing the RAM with battery

CNC 8060/8065/8070 CNC error · Fagor 8060/8065/8070

What it means

The startup test detected a checksum failure in battery-backed NVRAM, meaning the battery-backed memory area failed its integrity test. Data such as coordinates, zero offsets, parts counter and kinematics may not be valid. After replacing the battery the affected data must be re-entered and the machine re-homed.

Likely causes

  • exhausted lithium backup battery
  • battery holder/contact corrosion
  • NVRAM failure after prolonged operation with dead battery

Triage note: Replace the battery with the CNC powered ON if the manual for your hardware revision allows it, so retained data is not lost during exchange.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • lithium backup battery for CNC 8060/8065 central unit (verify ref. on unit label)

    battery · Primary suspect

    Request a quote →

Need the part urgently?

Send us alarm 0010 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog