Fagor alarm 0169: Safety temperature exceeded. Unit integrity at risk. Contact SAT

CNC 8060/8065/8070 CNC error · Fagor 8060/8065/8070

What it means

The CNC monitors its internal temperature every minute; three consecutive samples above 60 C raise this warning and activate the OVERTEMP PLC mark. Sustained overtemperature shortens component life and risks sudden shutdowns. The alarm text displays the current measured temperature.

Likely causes

  • blocked fan or failed cooling in the central unit
  • excessive ambient temperature or poor enclosure ventilation
  • enclosure clearances below Fagor recommendation around the unit

Triage note: Add enclosure fans or air conditioning if ambient exceeds spec; do not ignore - error 0173 will eventually inhibit START.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 0169 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog