Fagor alarm 070: X axis following error

Fagor legacy CNC error (8025/8040/8020) · Fagor legacy

What it means

Lag between commanded and actual X-axis position exceeded the permitted following-error window (codes 070-074 cover X, synchronized tool, Z and 3rd/4th axes). On this generation the alarm additionally trips the internal emergency output, dropping enables and analog outputs.

Likely causes

  • mechanical binding - gibs, lube failure, crashed screw
  • analog drive output dead or drive in fault
  • motor/feedback issue or grossly mistuned gain after parameter reload

Triage note: With power off, push the axis by hand to separate mechanical drag from servo issues before touching parameters.

Need the part urgently?

Send us alarm 070 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog