What it means

At power-up the 8025/8030 verifies parity of its battery-backed CMOS areas; the tool-offset and G53-G59 zero-offset block failed, indicating those contents were corrupted (classic dead-battery symptom). As part of recovery the CNC force-resets the RS232 serial parameters to defaults (P0=9600, P1=8, P2=0, P3=1, P605(5)=P605(6)=P605(7)=1).

Likely causes

  • backup battery below retention voltage (~2.7-3.0 V region)
  • power interruption during a table write
  • aging CMOS RAM losing bits

Triage note: Companion parity alarms 082, 095-099 hit the other areas (4th-axis, general parameters, Z, 3rd/C axis, X axis, M table). If several appear at once, treat the battery as dead and expect to reload all tables.