Fagor alarm 1015: The tool is not defined in the tool table
CNC 8055 CNC error · Fagor 8055/8055i
What it means
A tool change (T function) references a tool number that has no entry in the tool table. The CNC stops execution because offsets and geometry for the requested tool are unknown.
Likely causes
- typo in the T number versus the table
- tool table erased or partially loaded (e.g., after memory reload)
- table not updated when the job's tool list changed