Fagor alarm 1015: The tool is not defined in the tool table

CNC 8055 CNC error · Fagor 8055/8055i

What it means

A tool change (T function) references a tool number that has no entry in the tool table. The CNC stops execution because offsets and geometry for the requested tool are unknown.

Likely causes

  • typo in the T number versus the table
  • tool table erased or partially loaded (e.g., after memory reload)
  • table not updated when the job's tool list changed