Fagor alarm 1026: Wrong circular path with the programmed radius

CNC 8060/8065/8070 CNC error · Fagor 8060/8065/8070

What it means

In circular interpolation programmed with R, the radius value is geometrically inconsistent with start/end points, typically because it is too small to span the chord between them. The interpreter cannot construct the arc, so the block is rejected. Use center-format (I/J/K) programming for arcs close to half circles.

Likely causes

  • R smaller than half the distance between endpoints
  • endpoint coordinates mistyped
  • radius/diameter confusion on lathe X axis

Need the part urgently?