Fagor alarm 1035: Programmed "S" too high
CNC 8055 CNC error · Fagor 8055/8055i
What it means
The commanded spindle speed exceeds the maximum rpm allowed by the currently active gear range. The CNC rejects the S value rather than overspeeding the spindle.
Likely causes
- S value above MAXGEARn limit of the engaged range
- wrong gear selected (high-speed value commanded in a low range)
Need the part urgently?
Send us alarm 1035 with your machine details — typical RFQ turnaround is 24–48h.