Fagor alarm 106: Inside temperature limit exceeded

Fagor legacy CNC error (8025/8040/8020) · Fagor legacy

What it means

Internal temperature sensing in the 8025/8030 central unit reports the enclosure/electronics above its allowed limit. Continued operation risks component damage and memory errors, so the alarm demands attention to cooling before anything else.

Likely causes

  • cabinet fan failed or filter mat blocked
  • heat sources stacked next to the CNC unit
  • ambient temperature beyond the 45 C rating

Triage note: Sustained overheating accelerates EPROM/parity failures on these controls - fix airflow promptly.

Need the part urgently?

Send us alarm 106 with your machine details — typical RFQ turnaround is 24–48h.