Fagor alarm 1066: End of compensation without straight path

CNC 8055 CNC error · Fagor 8055/8055i

What it means

The first in-plane movement after canceling tool radius compensation (G40) was not a straight path. The cancellation lead-out must be linear for the CNC to unwind the offset, so the block is rejected.

Likely causes

  • G40 followed by a G02/G03 retract
  • compensation canceled inside a profile instead of on a linear exit move