Fagor alarm 1082: The probe signal has not been received
CNC 8055 CNC error · Fagor 8055/8055i
What it means
In a PROBE canned cycle the probe traversed the maximum safety distance of the cycle without the CNC seeing the touch signal, or in a G75 move the end point was reached with g.m.p. PROBERR (P119)=YES and no probe input transition. The measurement result is void; the CNC aborts rather than record a fictitious surface.
Likely causes
- broken probe cable, worn connector or failed opto-isolator input channel
- dead probe battery or damaged stylus (crashed probe)
- safety distance B too small for the approach feed used
- wrong probe input assigned in machine parameters
Triage note: Trigger the probe tip by hand in diagnostics and watch the input bit flip; no change means probe, cable or input stage.
Need the part urgently?
Send us alarm 1082 with your machine details — typical RFQ turnaround is 24–48h.