What it means

In a PROBE canned cycle the probe traversed the maximum safety distance of the cycle without the CNC seeing the touch signal, or in a G75 move the end point was reached with g.m.p. PROBERR (P119)=YES and no probe input transition. The measurement result is void; the CNC aborts rather than record a fictitious surface.

Likely causes

  • broken probe cable, worn connector or failed opto-isolator input channel
  • dead probe battery or damaged stylus (crashed probe)
  • safety distance B too small for the approach feed used
  • wrong probe input assigned in machine parameters

Triage note: Trigger the probe tip by hand in diagnostics and watch the input bit flip; no change means probe, cable or input stage.