RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 1084

Fagor alarm 1084: Arc programmed wrong

CNC 8055 CNC error · Fagor 8055/8055i

What it means

An arc definition is geometrically inconsistent: the IJK-plus-endpoint combination does not intersect, a three-point arc (G09) uses collinear or duplicate points, a tangential entry targets a path outside the active plane, or a tangential exit is followed by a path lying on the extension of the previous one. The CNC aborts block preparation.

Likely causes

  • end-point coordinates or I/J/K signs mistyped
  • three-point arc with duplicated or collinear points
  • plane (G16-G19) changed so the tangency no longer applies
  • variables producing degenerate geometry at runtime

Triage note: If the error points at a G66/G68/G69 call block, inspect the profile definition blocks themselves.

Need the part urgently?

Send us alarm 1084 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog