What it means

The CNC issued a velocity/output command to the spindle drive while the spindle SERVOSON enable input was still low. The drive therefore never becomes ready and the CNC flags the spindle as locked; motion and enables are shut down as with other servo-side errors.

Likely causes

  • PLC ladder not handling the SERVOSON signal correctly
  • spindle parameter DWELL(P17) too short for the drive's ready delay
  • drive ready relay/contact not closing (wiring or auxiliary supply issue)

Triage note: Error 1107 is the equivalent for spindle 2.