RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 1102

Fagor alarm 1102: Following error of spindle 1 out of limit

CNC 8055 CNC error · Fagor 8055/8055i

What it means

With the spindle closed in position loop (M19 oriented), the difference between commanded and actual spindle position exceeded spindle parameters MAXFLWE1(P21)/MAXFLWE2(P22). The CNC stops everything, cancels enables/analog outputs, opens the position loop if applicable, and additionally activates the external emergency relay output.

Likely causes

  • spindle drive fault or missing enable/power supply
  • defective spindle encoder feedback or feedback cable
  • velocity command cable broken (no +/-10V reaching drive)
  • mechanical overload - spindle binding or stiff
  • gain/limits tuned wrongly or defective CNC output stage

Triage note: Error 1108 reports the same fault for spindle 2. Systematic cause groups per Fagor: drive, motor/power cabling, feedback, mechanics, CNC/parameters.

Need the part urgently?

Send us alarm 1102 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog