RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 1108

Fagor alarm 1108: Following error of spindle 2 out of limit

CNC 8055 CNC error · Fagor 8055/8055i

What it means

Second-spindle version of error 1102: in closed-loop orientation the sub-spindle's following error exceeded MAXFLWE1(P21)/MAXFLWE2(P22). Full safety reaction applies - stop, enables removed, analog outputs canceled, external emergency output activated.

Likely causes

  • sub-spindle drive or its power/feed circuitry faulty
  • encoder or feedback cable defect on spindle 2
  • workpiece clamped so tightly/stalling the sub-spindle
  • incorrect gain or limit parameters for the sub-spindle

Triage note: Twin-spindle lathe models only.

Need the part urgently?

Send us alarm 1108 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog