Fagor alarm 1182-1190: Following error of * axis out of limit
CNC 8055 CNC error · Fagor 8055/8055i
What it means
The lag between commanded and actual position of the affected axis exceeded MAXFLWE1 (P21) or MAXFLWE2 (P22) of that axis - the classic servo-lag trip. Reaction: motion stop, enables dropped, analog outputs canceled, external emergency relay activated, position loop opened (LOPEN=1) and program interrupted.
Likely causes
- encoder/feedback cable damage or failing feedback device
- servo drive fault, missing enable or blown power stage
- velocity command (+/-10 V) not reaching the drive
- mechanical binding, stiction or lubrication loss on that axis
- following-error windows (P21/P22) tuned unrealistically tight
Triage note: Nine-code axis-mapped range (1182 = first axis). Swap feedback connectors between axes to split cable/device vs CNC board faults.
Need the part urgently?
Send us alarm 1182-1190 with your machine details — typical RFQ turnaround is 24–48h.