Fagor alarm 1182: X axis following error beyond limits (1183-1190 = Y/Z/U/V/W/A/B/C)
CNC 8055 servo error · Fagor 8055/8055i
What it means
Lag between commanded and actual position exceeded the value set in the axis following-error parameter during motion.
Likely causes
- mechanical binding - ways, lube starvation, way wipers, crashed screw
- drive not enabled / drive fault present
- motor or feedback (encoder/scale) failure
- gain (Kv) mistuned after parameter loss
Triage note: Triage order: jog axis by hand (power off) for binding -> confirm drive READY LED -> watch actual position vs dial indicator. Do NOT raise the following-error limit to hide a mechanical fault.
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
FXM34.40A (size-match per axis)
FXM synchronous servo motor · Common cause
- Request a quote →
AXD 2.50 (modular) / ACD 1.25 (compact)
Axis servo drive module · Common cause
- Request a quote →
EC-P-D / MPC-4xS-M
Feedback / motor power cable · Common cause
Need the part urgently?
Send us alarm 1182 with your machine details — typical RFQ turnaround is 24–48h.