RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 1191-1199

Fagor alarm 1191-1199: Difference of following errors of the slaved axis * too large

CNC 8055 CNC error · Fagor 8055/8055i

What it means

Two electronically coupled axes (or a gantry pair) drifted apart: the difference between their following errors exceeded the MAXCOUPE (P45) tolerance of the slave axis. This protects gantry geometry - both sides must track within tolerance or the CNC trips with the full emergency reaction including the external relay.

Likely causes

  • one side of the gantry mechanically bound or poorly lubricated
  • one drive/feedback of the pair degraded, tracking worse than its twin
  • MAXCOUPE(P45) set tighter than achievable by the mechanics
  • lost motion (backlash, loose coupling) on one side only

Triage note: Nine-code axis-mapped range identifying the slave ('n') axis.

Need the part urgently?

Send us alarm 1191-1199 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog