Fagor alarm 1191: Difference of following errors of the slaved X axis too large (1192-1199 = other gantry pairs)

CNC 8055 servo error · Fagor 8055/8055i

What it means

In a gantry/tandem pair the follower axis lags the master beyond tolerance - the pair is pulling against itself.

Likely causes

  • one side mechanically stiffer/looser (lube, gib, brake not releasing)
  • one drive weaker or dropping enable intermittently
  • feedback scale/encoder on one side drifting or losing counts

Triage note: Compare F.E. displays of both axes at standstill: the side with the non-zero lag is the suspect side.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 1191 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog