Fagor alarm 120: Checksum error recovering machine parameters from EEPROM

Fagor legacy CNC error (8025/8040/8020) · Fagor legacy

What it means

While restoring the locked machine parameters, decoded-M table and leadscrew compensation tables from EEPROM, the checksum did not match, so the recovered data cannot be trusted. The companion error 119 covers the failure to WRITE these areas; 120 covers a bad READ-BACK.

Likely causes

  • EEPROM cells worn after decades of rewrite cycles
  • interrupted save (error 119) leaving a partially written image
  • internal hardware fault in the EEPROM path

Triage note: Keep a paper/DNC copy of all locked parameters for this generation; EEPROM loss on a 40-year-old control is a when, not an if.

Need the part urgently?

Send us alarm 120 with your machine details — typical RFQ turnaround is 24–48h.