RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 1200-1208

Fagor alarm 1200-1208: Travel limits of the * axis exceeded

CNC 8055 CNC error · Fagor 8055/8055i

What it means

The axis ran into a physical travel limit and the PLC raised the LIMIT+1/LIMIT-1 mark for that axis. The CNC stops axis and spindle motion and removes enables/analog outputs; position-loop detection opens the loop and sets LOPEN=1, aborting the program.

Likely causes

  • overtravel into a hard-limit switch (crash, wrong jog direction)
  • dirty or misaligned limit switch triggering falsely
  • referencing error making the CNC believe it is past the physical stop

Triage note: Nine-code axis-mapped range (1200 = first axis); recover by jogging off the switch, then re-reference.

Need the part urgently?

Send us alarm 1200-1208 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog