Fagor alarm 1218-1226: Work zone 3 of the * axis exceeded

CNC 8055 CNC error · Fagor 8055/8055i

What it means

Motion tried to exit work zone 3 while it was set as a no-exit area (G22 K3 S2) - the target lies outside the allowed envelope for that axis. Usual stop-and-abort reaction applies; lift the restriction with G22 K3 S0 or correct the zone definition.

Likely causes

  • zone 3 boundaries defined against the wrong setup
  • program expecting a larger envelope than the zone permits
  • stale zone restrictions left from the previous part family

Triage note: Zone 4 equivalent: 1228-1236; zone 5: 1240-1248.