Fagor alarm 20001: Waiting for AUXEND from the PLC

CNC 8060/8065/8070 CNC error · Fagor 8060/8065/8070

What it means

An auxiliary function handed to the PLC (typically an M-function handshake) never received its AUXEND completion signal within the expected time - either legitimate slow machine logic or a stuck handshake. Press RESET to clear, then audit the PLC logic behind the auxiliary function for a missing branch that sets the completion mark.

Likely causes

  • PLC logic never sets AUXEND (unreachable branch, missing mark)
  • machine condition awaited by PLC not met (pressure, limit, sensor)
  • M-function finish signal wiring/inputs faulty

Triage note: Codes 20002-20028 share the pattern: the window names exactly which handshake (spindle stop, gear confirm, INPOS, etc.) timed out.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • sensor/limit switch gating M-function finish in PLC (identify via ladder)

    cable · Check if others ruled out

    Request a quote →

Need the part urgently?

Send us alarm 20001 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog