Fagor alarm 2010: Spindle feedback error (2029 = same for spindle 2)

CNC 8055 hardware/feedback error (analog axes) · Fagor 8055/8055i

What it means

No feedback signal reaching the CNC spindle input (A5/A6) - threaded cutting, rigid tapping and M19 orientation become impossible.

Likely causes

  • spindle encoder cable damaged or connector loose
  • spindle encoder (1000-1250 ppt class) failed
  • wrong parameter DIFFBACK(P14)/FBACKAL(P15) masking a real fault

Triage note: Check coupling between encoder and spindle first - slipped or broken dog teeth mimic a dead encoder.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 2010 with your machine details — typical RFQ turnaround is 24–48h.