RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 2012

Fagor alarm 2012: There is no voltage at the axis board

CNC 8055 servo error · Fagor 8055/8055i

What it means

The 24 V supply feeding the outputs of the axis board is missing. Without this voltage the CNC cannot assert the drive-enables and relay outputs that arm the SAC/SPC analog drives, so axes and spindle are stopped and the external emergency output fires. The usual culprit is the board's output-supply fuse or the upstream 24 V source.

Likely causes

  • blown fuse on the axis-board 24 V output supply
  • 24 V switched-mode supply in the cabinet dead or tripped
  • loose 24 V terminal or corroded connector on the axis board
  • wiring fault downstream shorting the 24 V output rail

Triage note: Restore 24 V and replace the fuse only after confirming no short; a repeatedly blowing fuse indicates a shorted output device or cable.

Need the part urgently?

Send us alarm 2012 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog