RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 2016

Fagor alarm 2016: The PLC is not ready.

CNC 8055 servo error · Fagor 8055/8055i

What it means

The CNC lost communication with a running PLC program: either no PLC program is loaded, the PLC watchdog tripped, or execution was halted from the monitor. Because ladder logic holds the drive-enable chain on analog 8055 systems, all motion stops and the external emergency output activates.

Likely causes

  • PLC program erased or not started after power-up
  • PLC watchdog error (execution overrun)
  • program interrupted from the PLC monitoring tool
  • corrupted user memory after battery failure

Triage note: Restart the PLC from the PLC mode screen; if the program is gone, reload from backup and then investigate why it did not execute.

Need the part urgently?

Send us alarm 2016 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog