Fagor alarm 2017: CNC RAM memory error.
CNC 8055 hardware/feedback error (analog axes) · Fagor 8055/8055i
What it means
The power-up diagnostic found a defect in the CNC's internal RAM. Machine data may be unreliable, so motion is inhibited and the external emergency output is activated. This is a board-level hardware verdict, not a parameter problem.
Likely causes
- failed RAM chip on the central CPU board
- memory damage from a previous power-supply surge
- severe electrical noise/ground fault stressing the board
Triage note: Board exchange via Fagor service; back up machine parameters once the unit runs again.