Fagor alarm 2017: CNC RAM memory error.

CNC 8055 hardware/feedback error (analog axes) · Fagor 8055/8055i

What it means

The power-up diagnostic found a defect in the CNC's internal RAM. Machine data may be unreliable, so motion is inhibited and the external emergency output is activated. This is a board-level hardware verdict, not a parameter problem.

Likely causes

  • failed RAM chip on the central CPU board
  • memory damage from a previous power-supply surge
  • severe electrical noise/ground fault stressing the board

Triage note: Board exchange via Fagor service; back up machine parameters once the unit runs again.

Need the part urgently?

Send us alarm 2017 with your machine details — typical RFQ turnaround is 24–48h.