RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 2025

Fagor alarm 2025: Probe feedback error

CNC 8055 hardware/feedback error (analog axes) · Fagor 8055/8055i

What it means

The CNC expects a valid probe signal path and finds none - the measuring probe is not connected or its cabling is wired incorrectly. Probing cycles are impossible and motion is stopped with the external emergency output raised. Documented in the ·M· model edition of the 8055 error manual.

Likely causes

  • probe cable unplugged at the table or spindle connector
  • broken probe stylus or internal probe fault
  • miswired probe interface (signal/repeat contacts swapped)
  • damaged probe input on the CNC or probe interface board

Triage note: Verify the probe signal with a multimeter at the CNC input (optocoupler input) before condemning the probe head.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 2025 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog