Fagor alarm 2036: The type of keyboard does not match the CNC model
CNC 8055 CNC error · Fagor 8055/8055i
What it means
At startup the 8055 reads the identifier returned by the keyboard and finds it unknown, i.e. the keyboard does not match the CNC configuration (mill vs. lathe keyboard, or a failed ID readback). Fagor lists contacting the Service Department as the remedy, since a wrong keyboard blocks correct key coding.
Likely causes
- swapped or substituted operator panel of the wrong model
- broken keyboard cable or connector interrupting the ID lines
- keyboard microcontroller unable to report its identifier
Triage note: Inspect the keyboard cable first: an intermittent ID read mimics a wrong-panel installation.
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
OP-8055 (model-matched operator keyboard)
operator panel / keyboard · Common cause
Need the part urgently?
Send us alarm 2036 with your machine details — typical RFQ turnaround is 24–48h.