RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 2043

Fagor alarm 2043: Parameters of the frequency filter set wrong.

CNC 8055 servo error · Fagor 8055/8055i

What it means

One or more values of the FAGOR frequency-filter parameter set are invalid, so the filters would remain inactive if execution continued. Detected at power-up or RESET after editing filter parameters. Since the filter shapes the servo command signal, running with inactive filters changes axis behavior and can provoke following-error problems.

Likely causes

  • typo/out-of-range value in filter frequency parameter
  • order/frequency combination not permitted by the CNC
  • parameters loaded from another machine model

Triage note: Correct frequency and order values per the 8055 parameter manual for each affected axis/spindle.

Need the part urgently?

Send us alarm 2043 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog