Fagor alarm 2051: Too many feedback pulses.

CNC 8055 hardware/feedback error (analog axes) · Fagor 8055/8055i

What it means

The feedback input of an axis is receiving pulses above what the counting electronics can process at the commanded speed - practically always the result of a gear ratio (or direct-drive coupling) that multiplies encoder frequency beyond the input limit at the programmed feedrate. The CNC halts and opens the loop rather than risk losing counts.

Likely causes

  • axis gear ratio parameter mismatched to the actual gearbox
  • feedrate/G00 rapid too high for the installed encoder line count
  • encoder mounted with wrong pulley ratio after a retrofit
  • parameter GEARRATIO/setpoint combination inconsistent

Triage note: Recompute pulses-per-mm against the mechanical ratio and correct GEARRATIO or reduce rapid; no component is failing.

Need the part urgently?

Send us alarm 2051 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog