Fagor alarm 2052: Too much real feedback difference.

CNC 8055 hardware/feedback error (analog axes) · Fagor 8055/8055i

What it means

On axes using dual feedback (motor encoder as first feedback plus a linear scale as second feedback), the CNC compares both positions continuously. The alarm fires when the difference exceeds a.m.p. FBACKDIF (P100), or - with the feedback-combination feature active - when the two count directions disagree or the divergence exceeds 838 mm. It indicates one feedback is slipping, losing counts, or scaled wrong.

Likely causes

  • linear scale reading wrong (contamination, damaged glass, loose read head)
  • motor encoder coupling slipping on the ball screw side
  • count direction of first and second feedback opposite (sign/pin swap)
  • FBACKDIF threshold unrealistic for the machine's lost motion
  • scale cable intermittently dropping counts

Triage note: Jog the axis slowly and watch both positions on the diagnosis screen: whichever feedback stays behind identifies the failing device. Setting FBACKDIF = 0 disables the check but masks a real fault.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 2052 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog