RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 24001

Fagor alarm 24001: EtherCAT: Datalink not found

CNC 8058/8060/8065/8070 CNCelite EtherCAT error (Quercus drives) · Fagor 8058

What it means

EtherCAT physical link lost - CNC sees no slave response on the bus (companion: 24002 missing package, 24003 CRC, 24004 working-counter).

Likely causes

  • EtherCAT cable disconnected or unlatched at a QC-DR drive or RIO node
  • slave drive powered down (its PSU stage dead)
  • EMC interference corrupting frames (24003 pattern)

Triage note: Read topology from the ENI/routed file: the first NON-responding slave after the last good one sits behind the broken cable. 24003 CRC errors repeating on one port = replace that specific cable segment.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • Cat5e/6 industrial EtherCAT cable (shielded, per length)

    EtherCAT bus cable · Primary suspect

    Request a quote →
  • QC-DR-012-FS1-B

    Quercus servo drive (silent/dead slave) · Common cause

    Request a quote →
  • RIOR-E-48I32O

    EtherCAT remote I/O (if fault isolates to I/O node) · Common cause

    Request a quote →

Need the part urgently?

Send us alarm 24001 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog