Fagor alarm 24003: EtherCAT: Wrong CRC

CNC 8058/8060/8065/8070 CNCelite EtherCAT error (Quercus drives) · Fagor 8058

What it means

Frames arrived on the EtherCAT bus with corrupted checksums, so they are discarded and the working counter degrades. The manual ties this to disconnection events or electromagnetic interference riding on the bus wiring.

Likely causes

  • bus cables routed next to power/brake chopper lines without shielding discipline
  • poor shield termination or missing ground bond at cabinet entry
  • intermittent connector contact raising bit errors

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 24003 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog