RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 3002

Fagor alarm 3002: WATCHDOG in the periodic module (PE).

CNC 8055 servo error · Fagor 8055/8055i

What it means

Same watchdog mechanism as 3001 but triggered by the periodic (PE) PLC module exceeding WAGPER (P1), typically due to heavy cyclic logic or an infinite loop. All enables drop and the external emergency output activates while the PLC is reset.

Likely causes

  • periodic module doing too much work each cycle
  • endless loop in periodic logic
  • WAGPER (P1) too small for the program
  • PLC timing parameters (CPUTIME P26 / LOOPTIME P72) misconfigured

Triage note: Move non-critical logic out of PE into PRG, or widen WAGPER; verify after edits that scan time stays within budget.

Need the part urgently?

Send us alarm 3002 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog