RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 3707

Fagor alarm 3707: Error when searching home

CNC 8060/8065/8070 servo/feedback error · Fagor 8060/8065/8070

What it means

Home-search cycle aborted: parameters wrong, counter module (RCS-S) fault, Sercos drive fault, feedback system fault or connection error.

Likely causes

  • reference mark (I0) missed due to dirty/damaged scale window
  • home switch out of position or dead (dog shifted after crash)
  • RCS-S Sercos counter module or drive homing hardware failing
  • REFPULSE/homing parameter mismatch

Triage note: Watch the home-switch input and the I0 diagnostics during the cycle: switch fires but no I0 within the rotation = scale/mark problem; neither appears = switch/wiring.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • SW-920 / S2X-320-5 (match axis)

    Linear scale (mark integrity) · Common cause

    Request a quote →
  • H-2500-C5

    Rotary encoder (rotary axes) · Common cause

    Request a quote →
  • RCS-S Sercos counter module (per machine OEM list)

    Remote counter module · Check if others ruled out

    Request a quote →

Need the part urgently?

Send us alarm 3707 with your machine details — typical RFQ turnaround is 24–48h.