Fagor alarm 3710: Position command values out of range

CNC 8060/8065/8070 servo/feedback error · Fagor 8060/8065/8070

What it means

An overflow occurred in the internal variable holding the position command sent to the axis. This is normally a configuration problem: the command computed from feedrate, pitch and electronic gearing exceeds the range representable in the position loop.

Likely causes

  • inconsistent PITCH, INPUTREV / OUTPUTREV gear-ratio parameters
  • feedrate programmed beyond what the resolution/gearing supports
  • wrong axis scaling after mechanical retrofit

Need the part urgently?

Send us alarm 3710 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog