RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 3717

Fagor alarm 3717: Some pulses got lost (not counted)

CNC 8060/8065/8070 servo/feedback error · Fagor 8060/8065/8070

What it means

Encoder exceeded maximum permissible turning speed; counts were dropped, reference (home) is invalid and displayed positions unreliable.

Likely causes

  • axis oversped (runaway, wrong gear ratio, Z-axis plummeting on brake loss)
  • encoder frequency limit lower than application demands (cable-length derating)
  • signal quality marginal at speed (shielding, cable capacitance)

Triage note: After ANY E3717 the machine reference is void - full home search mandatory. On vertical axes treat this as a safety event: verify the brake BEFORE restarting production.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • HP-1024-C5 (1 Vpp, 150 m reach)

    Higher-frequency rotary encoder · Common cause

    Request a quote →
  • SP-1024-R-C5-IP66

    Solid-shaft rotary encoder · Common cause

    Request a quote →
  • Brake/coil kit per axis OEM

    Vertical-axis motor brake (root cause on plummets) · Common cause

    Request a quote →

Need the part urgently?

Send us alarm 3717 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog