Fagor alarm 3732: Error in refreshing local counts
CNC 8060/8065/8070 servo/feedback error · Fagor 8060/8065/8070
What it means
The position loop detected an alarm on one of the local (onboard) count inputs while reading local feedback. The affected input cannot deliver usable pulses, so the corresponding axis feedback is considered invalid for the loop.
Likely causes
- short circuit or overload at the local feedback input
- broken signal wire between encoder/scale and the local input
- signal level out of specification (TTL 5 V differential)
- local counter input stage damaged