Fagor alarm 3753: Difference of position greater than MAXDIFREF. Press ENTER + RESET to confirm
CNC 8060/8065/8070 servo/feedback error · Fagor 8060/8065/8070
What it means
The absolute coordinate delivered by the feedback device differs from the coordinate saved in the previous CNC session by more than MAXDIFREF. The screen offers Current vs Expected Coordinate so the operator can accept the position or restore the expected one via G174 after confirming.
Likely causes
- genuine axis movement while the CNC was off
- linear scale or absolute encoder replaced/repaired without updating reference data
- feedback device failing intermittently and losing absolute information
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
Absolute linear scale SA / GA series
scale · Common cause
- Request a quote →
EEC-SP-x / EC-P-D feedback cable
cable · Common cause
Need the part urgently?
Send us alarm 3753 with your machine details — typical RFQ turnaround is 24–48h.