Fagor alarm 4000: Sercos ring error

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

SERCOS optical-fiber communication interrupted: ring broken, wrong baudrate/node-ID, incompatible drive firmware, or SERCOS board fault. All enables dropped, emergency output fired.

Likely causes

  • fiber optic cable broken, bent past radius, or dirty connector
  • drive powered down mid-operation (see error 4027)
  • SERCOSID wheel mismatch / SERSPD(P120) baudrate mismatch
  • CNC SERCOS board or drive SERCOS board failure

Triage note: Trace light physically around the ring OUT of CNC -> through each drive -> back IN. Remove drives from the ring one at a time; the segment that restores the ring locates the bad fiber or drive.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • QC-FBC-x (Quercus era) / DDS glass-fiber loop cable

    SERCOS fiber-optic ring cable · Primary suspect

    Request a quote →
  • AXD/SPD drive SERCOS mezzanine board

    Drive communication board (board-level swap) · Check if others ruled out

    Request a quote →