Fagor alarm 4001: Parameter LOOPTIME different at the CNC and at the drive

CNC 8060/8065/8070 SERCOS error · Fagor 8060/8065/8070

What it means

During ring initialization the CNC compares key synchronization parameters with each drive and found LOOPTIME disagreeing between the two sides. A common cycle time is mandatory for SERCOS phase 4, so the mismatch must be corrected before the bus becomes operational.

Likely causes

  • LOOPTIME changed at the CNC without re-parameterizing the drives
  • drive replaced with a unit storing a different cycle time
  • parameters not saved to flash after a drive service