Fagor alarm 4003: Overtemperature at the drive (107)

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

Drive standard error E107: temperature inside the drive enclosure (CPU/VeCon board area) is too high. The CNC executes its full stop sequence (enables off, program interrupted on all channels) with a category 1 controlled stop. Let the system cool and reduce ambient temperature before resetting.

Likely causes

  • Blocked cabinet ventilation or failed cabinet/drive fan
  • Ambient temperature above specification
  • Drive working continuously near its current limit