RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 4004

Fagor alarm 4004: Overtemperature at the motor (108)

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

Drive standard error E108: the motor thermal contact (PTC/thermistor in the feedback cable) reports excessive winding temperature. The CNC removes enables and interrupts the program with a category 1 stop. Allow the motor to cool for several minutes and lighten the duty cycle.

Likely causes

  • High current peaks demanded by the cycle
  • Defective temperature sensor in the motor
  • Damaged position-sensor cable carrying the thermal contact
  • Insufficient motor cooling (forced fan missing/faulty)

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 4004 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog