RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 4006

Fagor alarm 4006: Voltage control error (100...105)

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

Wrapper for internal supply rail errors E100-E105 (+/-5 V, +/-8 V, +/-18 V out of range). These errors cannot be reset from the CNC: after removing the cause the whole servo system must be powered down and back up. The CNC stops everything and fires its external emergency output when the rail fault appears.

Likely causes

  • Failure of the drive's internal switched-mode supply
  • Overloaded +18 V rail (e.g., defective IGBT driver stage)
  • Board-level component failure inside the drive

Triage note: Individual rails are reported as alarms 4056-4061.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 4006 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog