RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 4008

Fagor alarm 4008: Error at the power bus (213...215)

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

Wrapper for power-stage bus errors E213-E215: undervoltage at the IGBT driver, detected short-circuit, and hard overvoltage of the DC bus. All three interrupt the motor current instantly (category 0 stop) while the CNC cancels enables and aborts all channels. See the individual codes 4070-4072 for diagnosis.

Likely causes

  • Missing connection bridge of the internal ballast (E215)
  • External regen resistor disconnected or burned out (E215)
  • Shorted motor cable, phases touching, or failed IGBT (E214)
  • Defective IGBT gate-driver circuit (E213)

Triage note: Same drive errors also surface individually as 4070/4071/4072 and as bus-side 4077/4079.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 4008 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog