RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 4009

Fagor alarm 4009: Overcurrent (drive standard error 212)

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

Drive detected excessive current through its power stage (instantaneous trip, PWM cut, category 0 stop).

Likely causes

  • motor power cable shorted or grounded (coolant ingress at connector)
  • motor winding insulation failure
  • IGBT power stage failure inside the drive module
  • wrong motor data/current parameters causing overshoot

Triage note: If the trip occurs with the motor cable DISCONNECTED, the drive power stage is at fault; if not, isolate cable vs motor with an insulation test.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • MPC-4xS-M

    Motor power cable (megger before condemning drive) · Primary suspect

    Request a quote →
  • AXD 2.50 / ACD 1.25 (rating-match)

    Axis drive module (power stage) · Primary suspect

    Request a quote →
  • FXM55.12A (rating-match)

    Servo motor if megger fails · Common cause

    Request a quote →