Fagor alarm 4009: Overcurrent (drive standard error 212)
CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives
What it means
Drive detected excessive current through its power stage (instantaneous trip, PWM cut, category 0 stop).
Likely causes
- motor power cable shorted or grounded (coolant ingress at connector)
- motor winding insulation failure
- IGBT power stage failure inside the drive module
- wrong motor data/current parameters causing overshoot
Triage note: If the trip occurs with the motor cable DISCONNECTED, the drive power stage is at fault; if not, isolate cable vs motor with an insulation test.
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
MPC-4xS-M
Motor power cable (megger before condemning drive) · Primary suspect
- Request a quote →
AXD 2.50 / ACD 1.25 (rating-match)
Axis drive module (power stage) · Primary suspect
- Request a quote →
FXM55.12A (rating-match)
Servo motor if megger fails · Common cause
Need the part urgently?