Fagor alarm 4010: Overvoltage at the power bus (drive errors 304/306; 4011 = undervoltage, error 307)
CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives
What it means
DC-bus voltage rose above the hardware/software threshold - braking energy cannot be absorbed, or line supply is abnormal.
Likely causes
- external/internal ballast (braking) resistor open-circuit or burnt
- power supply module ballast/crowbar circuit failed
- mains spikes or heavily unbalanced/regenerative line (4011: mains <380 V, loose bus bars, blown PS fuse)
Triage note: Ohm-out the ballast resistor cold - an open ER resistor is the classic cause on vertical axes with fast decel. Undervoltage twin (4011/E307) points instead to line side: torque bus-bar screws and measure under load.