Fagor alarm 4011: Undervoltage at the power bus (307)

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

Drive standard error E307: the software has measured a DC bus voltage below the permissible minimum. It is a resettable error producing a category 1 controlled stop, with the usual CNC shutdown of enables and program. Check the mains side before blaming the drive.

Likely causes

  • Mains voltage below rated value (<380 V AC nominal systems)
  • Excessive line impedance under high current peaks
  • Loose bus plates, blown PSU fuse or missing line phase
  • Regenerative power supply module failing under load

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?