RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / 4027

Fagor alarm 4027: The drive has started up again

CNC 8055 SERCOS drive error (DDS) · Fagor DDS drives

What it means

A drive dropped and regained its auxiliary/control power during operation - SERCOS re-init trips the whole ring.

Likely causes

  • loose 24 V auxiliary supply wiring or failing APS-24 module
  • mains dips/contactors chattering feeding the PS module
  • drive internal power-supply stage intermittent (repeat offender = drive)

Triage note: Identify the culprit drive from the SERCOS LOG / its 7-segment display restart, then monitor its 24 V input with a chart recorder - dips point upstream, none point to the drive.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • APS-24

    Auxiliary 24 V DC supply module · Common cause

    Request a quote →
  • PS-25B4 / XPS-25

    Power supply module (control-power section) · Common cause

    Request a quote →
  • AXD/SPD affected size module

    Drive module if only one unit keeps resetting · Check if others ruled out

    Request a quote →

Need the part urgently?

Send us alarm 4027 with your machine details — typical RFQ turnaround is 24–48h.